Cable tray MKS-Magic® 110, unperforated FT

Parent Item no. cxmOID341954
  • Cable tray, side height 110 mm
  • Verband der Elektrotechnik, Elektronik, Informationstechnik e.V., Germany
  • Communautés Européennes, EC declaration of conformity according to EC directives
  • BET-tested to DIN EN 61537

Unperforated cable tray with integrated quick fastening system. The usable length of the cable tray is 3,000 mm.

All types

All types

Types Length Width Metal
thickness
Suitable for
maintaining electrical function
Item no. Quantity SSU
MKSMU 110 FT 3050 mm 100 mm 1 mm no 6059399
3 m
Cable tray MKS-Magic® 110, unperforated FT
Cable tray MKS-Magic® 110, unperforated FT

Cable tray MKS-Magic® 110, unperforated FT

Technical data

Plate thickness 1 mm
Connector version Integrated connector
Suitable for maintaining electrical function no
With cover no
Mounting perforation in base no
NATO hole pattern no
Usable cross-section 10800 mm²
Usable cross-section 108 cm²
Surface Hot-dip galvanised
Rustproof steel, pickled no
Side perforation no
Wide-span version no
Material description Steel

Dimensions

Length 3050 mm
Width 100 mm
Height 110 mm
Side height 110 mm
Dimension B 100 mm

Loads

Support spacing 1.5 m 1.85 kN/m
Support spacing 2.0 m 1.3 kN/m
Support spacing 2.5 m 0.75 kN/m
Support spacing 3.0 m 0.6 kN/m
MKSMU 115 FT 3050 mm 150 mm 1 mm no 6059401
3 m
Cable tray MKS-Magic® 110, unperforated FT
Cable tray MKS-Magic® 110, unperforated FT

Cable tray MKS-Magic® 110, unperforated FT

Technical data

Plate thickness 1 mm
Connector version Integrated connector
Suitable for maintaining electrical function no
With cover no
Mounting perforation in base no
NATO hole pattern no
Usable cross-section 16100 mm²
Usable cross-section 161 cm²
Surface Hot-dip galvanised
Rustproof steel, pickled no
Side perforation no
Wide-span version no
Material description Steel

Dimensions

Length 3050 mm
Width 150 mm
Height 110 mm
Side height 110 mm
Dimension B 150 mm

Loads

Support spacing 1.5 m 1.85 kN/m
Support spacing 2.0 m 1.3 kN/m
Support spacing 2.5 m 0.75 kN/m
Support spacing 3.0 m 0.6 kN/m
MKSMU 120 FT 3050 mm 200 mm 1 mm no 6059403
3 m
Cable tray MKS-Magic® 110, unperforated FT
Cable tray MKS-Magic® 110, unperforated FT

Cable tray MKS-Magic® 110, unperforated FT

Technical data

Plate thickness 1 mm
Connector version Integrated connector
Suitable for maintaining electrical function no
With cover no
Mounting perforation in base no
NATO hole pattern no
Usable cross-section 21800 mm²
Usable cross-section 218 cm²
Surface Hot-dip galvanised
Rustproof steel, pickled no
Side perforation no
Wide-span version no
Material description Steel

Dimensions

Length 3050 mm
Width 200 mm
Height 110 mm
Side height 110 mm
Dimension B 200 mm

Loads

Support spacing 1.5 m 1.85 kN/m
Support spacing 2.0 m 1.3 kN/m
Support spacing 2.5 m 0.75 kN/m
Support spacing 3.0 m 0.6 kN/m
MKSMU 130 FT 3050 mm 300 mm 1 mm no 6059405
3 m
Cable tray MKS-Magic® 110, unperforated FT
Cable tray MKS-Magic® 110, unperforated FT

Cable tray MKS-Magic® 110, unperforated FT

Technical data

Plate thickness 1 mm
Connector version Integrated connector
Suitable for maintaining electrical function no
With cover no
Mounting perforation in base no
NATO hole pattern no
Usable cross-section 32800 mm²
Usable cross-section 328 cm²
Surface Hot-dip galvanised
Rustproof steel, pickled no
Side perforation no
Wide-span version no
Material description Steel

Dimensions

Length 3050 mm
Width 300 mm
Height 110 mm
Side height 110 mm
Dimension B 300 mm

Loads

Support spacing 1.5 m 1.85 kN/m
Support spacing 2.0 m 1.3 kN/m
Support spacing 2.5 m 0.75 kN/m
Support spacing 3.0 m 0.6 kN/m
MKSMU 140 FT 3050 mm 400 mm 1 mm no 6059407
3 m
Cable tray MKS-Magic® 110, unperforated FT
Cable tray MKS-Magic® 110, unperforated FT

Cable tray MKS-Magic® 110, unperforated FT

Technical data

Plate thickness 1 mm
Connector version Integrated connector
Suitable for maintaining electrical function no
With cover no
Mounting perforation in base no
NATO hole pattern no
Usable cross-section 43800 mm²
Usable cross-section 438 cm²
Surface Hot-dip galvanised
Rustproof steel, pickled no
Side perforation no
Wide-span version no
Material description Steel

Dimensions

Length 3050 mm
Width 400 mm
Height 110 mm
Side height 110 mm
Dimension B 400 mm

Loads

Support spacing 1.5 m 1.85 kN/m
Support spacing 2.0 m 1.3 kN/m
Support spacing 2.5 m 0.75 kN/m
Support spacing 3.0 m 0.6 kN/m
MKSMU 150 FT 3050 mm 500 mm 1 mm no 6059409
3 m
Cable tray MKS-Magic® 110, unperforated FT
Cable tray MKS-Magic® 110, unperforated FT

Cable tray MKS-Magic® 110, unperforated FT

Technical data

Plate thickness 1 mm
Connector version Integrated connector
Suitable for maintaining electrical function no
With cover no
Mounting perforation in base no
NATO hole pattern no
Usable cross-section 54800 mm²
Usable cross-section 548 cm²
Surface Hot-dip galvanised
Rustproof steel, pickled no
Side perforation no
Wide-span version no
Material description Steel

Dimensions

Length 3050 mm
Width 500 mm
Height 110 mm
Side height 110 mm
Dimension B 500 mm

Loads

Support spacing 1.5 m 1.85 kN/m
Support spacing 2.0 m 1.3 kN/m
Support spacing 2.5 m 0.75 kN/m
Support spacing 3.0 m 0.6 kN/m
MKSMU 160 FT 3050 mm 600 mm 1 mm no 6059411
3 m
Cable tray MKS-Magic® 110, unperforated FT
Cable tray MKS-Magic® 110, unperforated FT

Cable tray MKS-Magic® 110, unperforated FT

Technical data

Plate thickness 1 mm
Connector version Integrated connector
Suitable for maintaining electrical function no
With cover no
Mounting perforation in base no
NATO hole pattern no
Usable cross-section 65500 mm²
Usable cross-section 655 cm²
Surface Hot-dip galvanised
Rustproof steel, pickled no
Side perforation no
Wide-span version no
Material description Steel

Dimensions

Length 3050 mm
Width 600 mm
Height 110 mm
Side height 110 mm
Dimension B 600 mm

Loads

Support spacing 1.5 m 1.85 kN/m
Support spacing 2.0 m 1.3 kN/m
Support spacing 2.5 m 0.75 kN/m
Support spacing 3.0 m 0.6 kN/m
Technical data

Technical data

Load diagram, cable tray, type MKSMU 110

Load diagram, cable tray, type MKSMU 110
  • Permitted cable tray/ladder load in kN/m without man load Permitted cable tray/ladder load in kN/m without man load
  • Support width in m Support width in m
  • Rail bend in mm at permitted kN/m Rail bend in mm at permitted kN/m
  • Load scheme during testing Load scheme during testing
  • Load curve with cable tray/ladder width in mm Load curve with cable tray/ladder width in mm
  • Strut bend curve according to support width Strut bend curve according to support width
3D data
Invitation to tender text

Invitation to tender text

MKSMU 110 FT / 6059399
Download
MKSMU 115 FT / 6059401
Download
MKSMU 120 FT / 6059403
Download
MKSMU 130 FT / 6059405
Download
MKSMU 140 FT / 6059407
Download
MKSMU 150 FT / 6059409
Download
MKSMU 160 FT / 6059411
Download
Downloads